Leave Your Message
Products Categories
Featured Products

French Standard Industrial Cables U-1000 AR2V

Working Voltage: 600/1000 volts

Test Voltage: 1200 volts

Minimum Bending Radius: 6 x Ø

Operation Temperature Range: -10 °C to 60 °C

Short-circuit Temperature: 250 °C

Flame Retardant: NF C 32-070 C2

Insulation Resistance: 20 MΩ x km

    products description

    Application and Description
    These cables for energy distribution are suitable for all types of low voltage industrial-type connection, in urban grids, building installations, etc. Particularly suited in cases of high operating temperature and when high resistance to solar radiation and atmospheric agents is required. Good resistance to low temperature and chemical agents. Can be used without additional mechanical protection in the open air, fixed to walls or in raceways, inside walkways, and in empty in Cable Constructions in general. Can be laid underground with mechanical protection constructed from slabs, tiles, or bricks. They are not recommend to lay this cable in ground flooded for more than two months per year. With appropriate mechanical protection it can be use in areas subject to risk of explosion, but in this case the permitted current load is reduced by 15%. It can be used in ambient temperature down to -25°.
    Standard and Approval
    XP C 32-321(formerly NF C 32-321), EN 60332-1/NF C 32-070
    Cable Construction
    - Flexible aluminum strands
    - Strands to IEC 60228 class 2
    - XLPE insulation according to XP C 32-321
    - Color codes to XP C32-321
    - Not fibrous and not hygroscopic filler
    - Flexible black PVC outer jacke
    AWG(MCM) Cross Section mm² Insulation thickness mm Minimum Sheath thickness mm Maximum Overall diameter mm Approx Cable weight kg/km
    2 1x35 0.9 1.09 13.5 190
    1 1x50 1.0 1.09 15 245
    2/0 1x70 1.1 1.09 17 325
    3/0 1x95 1.1 1.18 19 425
    4/0 1x120 1.2 1.18 21 520
    300MCM 1x150 1.4 1.26 23 630
    500MCM 1x185 1.6 1.26 25.5 780
    750MCM 1x240 1.7 1.35 28.5 990
    - 1x300 1.8 1.43 31 1210
    - 1x400 2.0 1.52 34.2 1510
    - 1x500 2.2 1.6 38 1860
    - 1x630 2.4 1.77 44 2400
    AWG(MCM) Cross Section mm² Insulation thickness mm Minimum Sheath thickness mm Maximum Overall diameter mm Approx Cable weight kg/km
    8 2x10 0.7 1.43 16 275
    6 2x16 0.7 1.43 18.5 360
    4 2x25 0.9 1.43 22 530
    2 2x35 0.9 1.43 24.5 640
    AWG(MCM) Cross Section mm² Insulation thickness mm Minimum Sheath thickness mm Maximum Overall diameter mm Approx Cable weight kg/km
    8 3x10 0.7 1.43 17 300
    6 3x16 0.7 1.43 19.5 400
    4 3x25 0.9 1.43 23.5 600
    2 3x35 0.9 1.43 26 750
    1 3x50 1.0 1.43 29 970
    2/0 3x70 1.1 1.52 34 1310
    3/0 3x95 1.1 1.6 38.5 1730
    4/0 3x120 1.2 1.69 42.5 2120
    300MCM 3x150 1.4 1.86 47.5 2640
    500MCM 3x185 1.6 1.94 53 3290
    750MCM 3x240 1.7 2.11 59.5 4210
    - 3x300 1.8 2.28 66 5210
    AWG(MCM) Cross Section mm² Insulation thickness mm Minimum Sheath thickness mm Maximum Overall diameter mm Approx Cable weight kg/km
    4 4x25 0.9 1.43 25.5 720
    2 4x35 0.9 1.43 28.5 910
    1 3x50+35 1.0 1.52 31.1 1130
    2/0 3x70+50 1.1 1.6 36.2 1540
    3/0 3x95+50 1.1 1.69 40.6 1940
    4/0 3x120+70 1.2 1.86 45.4 2430
    300MCM 3x150+70 1.4 1.94 49.5 2890
    500MCM 3x185+70 1.6 2.11 54.5 3660
    750MCM 3x240+95 1.7 2.28 61.5 4680